A special system restore procedure is required after exchanging modules. It is described
in 5.2.1– 5.2.6 below.
5.2.1 Exchanging T24KeypadRFID– With System Restore
You need to disconnect the door station’s power supply
before exchanging the keypad. To restore the system after
exchanging it, you will need an up-to-date backup of the
system configuration.
Proceed As Follows:
1. Disconnect the door station from the power supply (for
example, remove the network plug).
2. Remove the keypad to be exchanged from the module frame as described in the
T24 System Manual Part 1/Section 2.4.6 (Removing And Exchanging Modules).
3.
Exchange the keypads. Take care not to damage the cabling or mix up the connections.
The connection diagrams are provided in the T24 System Manual Part 1.
4. Reconnect the power supply, wait until the system has booted and run a system
restore via the video phone, as described in 5.2. The door station is now ready
for operation and can once again be used with the PINs and transponder cards
set up for your system.
5.2.2 Exchanging T24-DoorMaster– With System Restore
You need to disconnect the door station’s power supply before
exchanging the T24-DoorMaster. To restore the system after
exchanging it, you will need an up-to-date backup of the
system configuration.
Proceed As Follows:
1.
Disconnect the door station from the power supply (for example, remove the network
plug).
2. Exchange the T24-DoorMaster. Take care not to damage the cabling or mix up the
connections. The connection diagrams are provided in the T24 System Manual Part 1.
3. Reconnect the power supply, wait until the system has booted and run a system
restore via the video phone, as described in 5.1. The door station is now ready
for operation and can once again be used with the PINs and transponder cards
set up for your system.
Contact your MOBOTIX
support team to
exchange a (used)
T24-KeypadRFID
and T24-DoorMaster
that no longer have
factory default con-
dition (the devices
will need to undergo
a hardware reset)
Przeglądanie stron 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 119 120

Komentarze do niniejszej Instrukcji

Brak uwag