2.9.9 Camera Startup Sequence
As soon as the camera's power supply has been established, the two LEDs will show the
progress of the startup sequence (see
Section5.4.3, «LED Signals and LED Configuration»
in the MOBOTIX
Camera
Software Manual
).
•
Booting: Immediately after connecting the power supply, the red LED lights up, flashes
for two seconds, then stays on permanently red. A camera self-test is carried out at
this point, and the entire system is started. In case of an error, the camera will start
using the backup system.
• Waiting for key pressed: Both LEDs light up for four seconds. If you press the R or L
key of the camera during this time, the camera will execute the corresponding func-
tion (see
Section 3.2.6, «Starting the Camera with an Automatic IP Address (DHCP)»
and
Section 3.2.5, «Starting the Camera with the Factory IP Address»
). Use a suitable
device to press a key (a ball-point pen, for example).
•
Ready: Once the camera software has been started, the green LED is on permanently
and the red LED blinks. You can now reach the camera via the network using a browser.
Notes
During the startup sequence of the camera, the LEDs will always light up, even if
they have been deactivated in Admin Menu> LED Setup.
LED default settings:
1 Power (on),
Error (ashing)
2 Recording (ashing)
1
2
R L