Installation In The Siedle Vario System
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
2.9.3 Preparing Network And Power Connections
The door station requires the following basic cabling:
•
(A) Ethernet cable from the PoE switch (or from a router with additional PoE power supply)
• (B) Two wires for powering the Siedle modules from the transformer in the electrical cabinet
• (C) Two wires for the anti-theft protection controller in the electrical cabinet (optional)
• (D) Two wires for the 230 V light relay
• (E) Cables to the external door opener, door contact and door lock switch
Safety Warning
Never connect or handle live cables (for example, a 240 V power supply) on your
own; always have a trained electrician do the installation.
Recommendation For Cabling
As a specification for cable line A (network), MOBOTIX recommends using a category 5
(Cat 5) Ethernet installation cable or higher. For cable lines B, C and D, we recommend
laying an 8- or 10-wire YSTY (telephone) cable with 0.8 mm core diameter, even in the
case of smaller installations, to make future expansion more convenient. As a rule, however,
when maximum cable lengths are kept low, YSTY (telephone) cable with only a 0.6 mm
core diameter may also be used. When laying the cable, ensure that sucient length
remains in reserve on the door station end for later extensions or for swapping modules
(lay a cable loop). All two-wire cables should be fed in through a in-wall socket on the
inside of the door with sucient space for cable reserves. Both the network
cable and other cables must be stripped at the ends.